Protein L Acceptor Beads
SKU: 29156499832

Protein L Acceptor Beads

Sale price$321.30 Regular price$357.00
Save 10%

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jul 8 - Jul 13

Promo Codes Available:

For Your Every Summer RSVP, with Code: SUMMER15

Description

Protein L Acceptor BeadsProduct Specification Stability & Storage Store at 28, protected from light; product shelf life is 12 months. Background Homogeneous Immuno Chemiluminescence Assay (HICA) is a homogeneous immunoassay method based on energy transfer between donor beads and acceptor beads at close proximity, resulting in luminescence. Donor beads recognize Protein 1 (Tag1 label), while Acceptor beads recognize Protein 2 (Tag2 label). When Protein 1 binds to Protein 2,

Product Specification


Stability & Storage

Store at 2~8℃, protected from light; product shelf life is 12 months.

Background

Homogeneous Immuno Chemiluminescence Assay (HICA) is a homogeneous immunoassay method based on energy transfer between donor beads and acceptor beads at close proximity, resulting in luminescence.

Donor beads recognize Protein 1 (Tag1 label), while Acceptor beads recognize Protein 2 (Tag2 label). When Protein 1 binds to Protein 2, the distance between the beads becomes less than 200nm. Upon excitation at 680nm, the donor beads generate singlet oxygen, which diffuses to the acceptor beads. The acceptor beads then undergo a redox reaction, emitting light at 615nm. The signal intensity is proportional to the strength of the protein interaction.

This product features a simple operation process, requires no washing, and offers high speed and sensitivity. It can detect weak interactions.

Components

Specification

Fill Volume

250 μg

50 μL

5 mg

1 mL

25 mg

1 mL x 5


Protocol

[Required Reagents]

Name

Catalog No.

Protein L Acceptor Beads UA086098
Streptavidin Donor Beads UA086104
Universal Buffer 1 UA086113


[Detection Protocol for Reference]

Detection Protocol

Detection Protocol 1 (37℃Rapid Detection)

Detection Protocol 2 (Room Temperature Detection)

Step 1:

4μL Tag1-M1 +4μL Tag2-M2+ 6μL Acceptor Beads,Avoid Light / Green Light

4μL Tag1-M1 +4μL Tag2-M2+ 6μL Acceptor Beads,Avoid Light / Green Light

Incubation

37℃ Shaking Incubation 20 minutes,Avoid Light / Green Light

Room Temperature Incubation 60 minutes,,Avoid Light / Green Light

Step 2:

Add 6μL Donor Beads,Avoid Light / Green Light

Add 6μL Donor Beads,Avoid Light / Green Light

Incubation

37℃ Shaking Incubation 10 minutes,Avoid Light / Green Light

Room Temperature Incubation 30 minutes,Avoid Light / Green Light

Reading

Instrument Reading

Instrument Reading


[Performance Validation]

Sample Preparation:

Use Universal Buffer 1 to pre-dilute Biotinylated Human IgG (Bio-hIgG) to 15μg/mL (100nM) as stock solution, then perform serial dilution according to the following scheme:

ID

Final Concentration (nM)

Universal Buffer 1

Volume (μL)

High Concentration Addition

Volume (μL)

C12

1.0E+01

210

90μL Stock Solution

C11

3.0E+00

210

90μL C12

C10

1.0E+00

180

90μL C11

C9

3.0E-01

210

90μL C10

C8

1.0E-01

180

90μL C9

C7

3.0E-02

210

90μL C8

C6

1.0E-02

180

90μL C7

C5

3.0E-03

210

90μL C6

C4

1.0E-03

180

90μL C5

C3

3.0E-04

210

90μL C4

C2

1.0E-04

180

90μL C3

C1

0

180

/


Detection Reagent Preparation:

Name

Preparation Concentration

Diluent

Protein L Acceptor Beads

25 μg/mL

Universal Buffer 1

Streptavidin Donor Beads

25 μg/mL

Universal Buffer 1


37℃Incubation Mode Results:

Maximum Signal: 5917193

Minimum Signal: 1725

EC50= 0.402 nM

Room Temperature Incubation Mode Results:

Maximum Signal: 2253290

Minimum Signal: 882

EC50= 0.371 nM

Guidelines

1. This experiment is light-sensitive; ensure all operations are performed in the dark. It is recommended to conduct preparation, sample loading, and incubation under green light (illuminance below 100 LUX). 2. This product is compatible with multi-mode microplate readers equipped with an Alpha detection module. 3. Vortex thoroughly before use, or briefly centrifuge (2000×g, 5–10 seconds) to ensure complete sample retrieval. 4. It is recommended to use the accompanying dilution buffer for reagent preparation and sample dilution. If additional components are required, they can be directly added to this buffer. 5. To ensure comparability of experimental data across different batches, strictly control incubation temperature and duration. 6. Avoid generating bubbles during sample loading.
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy
SKU: 29156499832

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

4.6 ★★★★★
Based on 2000 reviews
Sort
Highest Rating
Newest First
Oldest First
Product Reviews
S
Verified Purchase
Steve just Steve
Birmingham, US
★★★★★ 5
Nice set of balls
Size: Medium
The squeaker quickly became my dog’s favorite ball and has replaced the fuzzy tennis balls. My dog is a nonstop fetcher and these chuck it balls are durable and fun.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on January 9, 2026
C
Verified Purchase
Claudia Garfield
Carnegie, US
★★★★★ 5
Perfect ball
Size: Medium
Our dog loves these!
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 26, 2026
T
Verified Purchase
Timothy john starkweather
Draper, US
★★★★★ 4
Soild
Size: Medium
The orange and blue ball is perfect. Once start taken because the because the blue noisy one was a little to easy for my dog to start ripping pieces off. Will say most toys do not survive his chewing.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on January 24, 2026
C
Verified Purchase
Christy D.
Grantham, US
★★★★★ 5
Aggressive chewer who loves fetch approved!!
Size: Medium, Size: Medium
I highly recommend the Chuck-It brand in general, especially for dogs with an aggressive bite. These balls are awesome and are the most durable balls I’ve bought for my 50 lbs lab mix. He has not been able to break one of them yet and we’ve had a few of the squeaky balls for months. They are a bit pricey but worth it. The one in the pic has been used for months, lives outside and you can see it’s still in great shape.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on June 22, 2025
T
Verified Purchase
Tasha U
Lake Worth, US
★★★★★ 5
Good quality dog ball for playing fetch
Size: Medium
My dog and family love these chuck it balls to play fetch with our dog. They are durable and fun. They squeak which is added fun for any dog! Regular tennis balls my dog chews apart and they get pretty gross after playing and being left outside. These can be easily washed off and cleaned. These balls last! Would recommend to anyone with a dog and would purchase again.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on April 17, 2025

recommand products